Upload UV–Vis data — calculate band gap from UV–Visible spectra
Drop a spectrophotometer export here (absorbance or transmittance) or clickUpload file — the Tauc plot, linear fit and optical band gap Eg are produced in your browser.
Raw ASCII exports from Shimadzu, PerkinElmer, Cary, Jasco and Ocean Optics · parsed locally, never uploaded
| Column 1 | Column 2 |
|---|
| R² (determination) | 0.9972 |
| Linear slope (m) | 12.450 |
| Y-intercept (b) | -30.751 |
| Fit range | 2.31–2.82 eV |
| Fitted points | 42 |
| Fit quality | Good |
| Transition | Direct allowed |
| Method | Absorbance-based |
Linear fitting region
Select the fundamental absorption onset
Automatic suggestion — verify the range manually before publishing.
Analysis settings
Step 2 · ParameterizeAbsorbance and transmittance stay here, in the calculator. Axis unit, transition model, analysis mode and advanced options live in the More settingspopup; the fitting window lives in the Linear fitting popup.
Processed Scientific Coordinates
Tabular numerical dataset transformed for regression and export
Understanding Tauc Plot Analysis & Optical Band Gap Calculation from UV–Vis Spectra
Authoritative physics reference for solid-state physicists, materials scientists, and nanotechnologists
1. Davis–Mott and Tauc Formulation
The optical absorption coefficient α of amorphous and crystalline semiconductors near the absorption edge is governed by the Davis–Mott power law:
In a standard Tauc plot, photon energy hν (in eV) is plotted on the abscissa (X-axis), and (αhν)n is plotted on the ordinate (Y-axis). By performing linear regression along the fundamental absorption onset and extrapolating the line down to y = 0, the optical band gap Eg is precisely determined as Eg = −b / m.
2. How to Choose Transition Exponent (n)
The exponent n depends directly on the electronic band structure of the material:
- Direct Allowed (n = 2): Valence band maximum and conduction band minimum coincide at the same k-vector (Γ point). Photons excite electrons directly without lattice phonons. Common examples include ZnO, GaAs, InP, CdTe, and metal halide perovskites.
- Indirect Allowed (n = 1/2): The band extrema occur at differing crystal momentum vectors (Δk ≠ 0). Conservation of momentum requires simultaneous emission or absorption of a crystal phonon. Examples: Silicon (Si), Germanium (Ge), and Anatase TiO2.
- Direct Forbidden (n = 2/3): Transitions where the electric dipole matrix element vanishes at k = 0 by parity selection rules (e.g. Cu2O).
- Indirect Forbidden (n = 1/3): Phonon-assisted transitions whose dipole matrix element also vanishes (e.g. SnO2 and some metal oxides).
3. Avoiding Common Pitfalls: The Urbach Tail
Real semiconductor samples possess localized defect states, grain boundaries, and thermal lattice vibrations that cause exponential absorption below the nominal band gap (known as the Urbach tail).
Fitting the sub-bandgap tail rather than the true interband absorption edge will systematically underestimate Eg. Our calculator's interactive fitting sliders allow researchers to visually restrict the regression span exclusively to the steep, linear onset. Open the Linear fitting popup (from the Analysis settings panel or the button under the graph) to set the fitting range, or the More settings popup to change the transition model and the analysis mode without losing sight of the plot.
4. UV–Vis Spectrophotometer Data Compatibility
This web application parses ASCII numerical data tables exported from major optical spectroscopy systems:
- Shimadzu UV-2600 / UV-3600 (UVProbe / LabSolutions)
- PerkinElmer Lambda 750 / 950 / 1050 (UV WinLab)
- Agilent Cary 60 / 5000 (Cary WinUV)
- Jasco V-770 / V-670 (Spectra Manager)
- Ocean Optics / Ocean Insight spectrometers
5. Tauc Plot from CSV, TXT and Other Raw Exports
Build a Tauc plot from CSV data or from a plain TXT file by dropping the export straight onto the upload tile: the parser detects the delimiter, skips header and comment rows, and lets you map the horizontal column (wavelength, energy or 1/λ) against the signal column (absorbance, %T, fractional transmittance or α).
- Supported extensions: .csv, .txt, .dat, .tsv, .asc
- Delimiters: comma, semicolon, tab and whitespace — detected automatically
- Every conversion runs locally; the spectrum is never uploaded to a server
6. Linear Fitting, Regression and Export
The Tauc plot linear fitting controls propose an automatic range and then let you set the fitting window by hand, so the extrapolation covers the fundamental absorption onset and never the Urbach tail. Every fit reports the slope m, the intercept b, R² and the extrapolated band gapEg = −b/m — a Tauc plot regression calculator and extrapolation calculator in one instrument.
Export the figure as a vector Tauc plot SVG, a 300 dpi PNG or a CSV/TXT data table: a publication-ready, publication-quality Tauc plot for a research paper, generated from your own spectrum in seconds. Use your browser's print dialog on the exported SVG when a journal asks for a PDF.
More settings
Units · Transition · ModeConversion to photon energy (hν) is applied automatically.
Direct dipole-allowed electronic transition across the band edge (n = 2). Typical for: ZnO, GaAs, CdTe, Perovskites.