Same equation, different exponent. What n = 2 and n = 1/2 actually mean physically, how each curve looks, and how to choose the right Tauc exponent for your material.
A direct band gap Tauc plot and anindirect band gap Tauc plot use the same equation but a different exponent: n = 2 for a direct allowed transition and n = 1/2 for an indirect allowed one. The exponent is not a fitting preference — it reflects whether the electron can cross the gap without a phonon.
Choosing the wrong n changes the shape of the curve, moves the linear onset, and shifts the extrapolated band gap. This page explains the physics behind the two models and how to decide which exponent belongs to your material — before you fit anything.
| Property | Direct allowed | Indirect allowed |
|---|---|---|
| Exponent n | 2 | 1/2 |
| Plotted y-value | (αhν)² | (αhν)^(1/2) |
| Momentum rule | Δk = 0 — vertical transition | Δk ≠ 0 — phonon required |
| Band structure | Conduction band minimum above valence band maximum at the same k | Minimum and maximum at different k points |
| Edge sharpness | Usually steeper, well-defined onset | Broader onset, phonon-assisted tail |
| Typical materials | ZnO, GaAs, CdTe, MAPbI₃, GaN | Si, Ge, anatase TiO₂, GaP, AlAs |
| Typical Eg | Often 1.5–3.5 eV for semiconductors | Si ≈ 1.1–1.2 eV, Ge ≈ 0.66 eV |
Raising αhν to the power of 2 stretches the upper part of the absorption edge and sharpens the onset; taking the square root compresses it and softens the edge. In practice:
When the dipole matrix element vanishes at k = 0, the transition is forbidden and the exponent changes again: n = 2/3 for direct forbidden (Cu₂O, SnO) and n = 1/3 for indirect forbidden (SnO₂, some rare-earth oxides). These models are far less common — reach for them only when the allowed model clearly fails and the literature for your material supports it.
Band-structure alignment decides n before you open a file. These worked material cases show what the right model looks like in practice — and roughly where a correct Tauc fit should land against the literature.
VBM at Γ, CBM near X — phonon-assisted absorption. Optical gaps from Tauc fits on high-quality c-Si sit near 1.1–1.2 eV, consistent with the 1.12 eV indirect gap. Forcing n = 2 on Si bends the onset and typically inflates the intercept.
VBM and CBM both at Γ. Clean films show a steep (αhν)² edge and Eg around 3.2–3.4 eV depending on defects and morphology. Using n = 1/2 softens the edge and often lands several hundred meV low.
Indirect edge with a direct transition higher in energy. Fit the first rising edge with n = 1/2 (often ~3.2 eV); do not chase the steeper shoulder with n = 2 unless you are intentionally reporting the direct gap.
Direct gap near Γ, commonly reported 1.5–1.6 eV. Thin-film interference and Urbach tails are frequent; keep the window on the straight onset and exclude the low-energy tail before quoting Eg.
Reproduce the fits with the bundled sample datasets on theexamples page, or switch exponents live in thecalculator.
For a direct allowed transition the exponent is n = 2, so the plotted quantity is (αhν)² against photon energy.
For an indirect allowed transition the exponent is n = 1/2, so the plotted quantity is the square root (αhν)^(1/2) against photon energy.
Yes. Because each exponent reshapes the curve, the linear onset moves and the extrapolated intercept changes. Using the wrong model is one of the most common sources of disagreement with literature values.
Yes. Many semiconductors have a lower indirect edge and a higher direct edge. Fitting the wrong shoulder of the absorption spectrum mixes the two transitions and reports a gap that matches neither.
A band-structure plot shows whether the VBM and CBM share the same k-point. Direct alignment → start with n = 2; staggered extrema → n = 1/2. Use the plot only after the band structure is clear — never the reverse.
Direct forbidden (n = 2/3) and indirect forbidden (n = 1/3) arise when the dipole matrix element vanishes at the band edge, so absorption rises with a higher power of (hν − Eg). SnO₂ and Cu₂O are classic cases.
Switch exponents in the calculator and watch the fitted band gap update — a quick way to see how much the transition model matters.